Pengaruh Penambahan Sikament-Nn Dan Silica Fume Terhadap Kuat Tekan Beton SCC (Self Compacting Concrete)
DOI:
https://doi.org/10.51135/manumatav9i1p57-63Keywords:
Aggregates, Added Materials (Admixture), ConcreteAbstract
In carrying out construction and other infrastructure, the community, both service providers and service users of Ambon City, do not clearly know the use of Sikament-NN and Silica fume for the compressive strength of concrete, which is in accordance with the material conditions, both cement and available aggregate. This research was conducted to determine the aggregate characteristics, mix design, the results of the comparison of the compressive strength of concrete with the use of Sikament-NN and Silica fume additives and a combination of the two additives, as well as the effect of the addition of Sikament-NN and Silica fume and a combination of the two additives on the compressive strength of concrete. SCC (Self Compacting Concrete). The data collection process was carried out using the experimental method, namely the researcher directly conducted the research and took the required data related to the testing that the researcher was doing. Therefore the researchers tested the aggregate characteristics, concrete mix design using SNI 03-2834-2000 and f'c design compressive strength of 30 MPa. The results of the fine aggregate characteristic study obtained Wv 1.22 gr/cm3, BJAH 2.51, WC 6.43%, MHB 3.09, C 1.90% and the organic content was light yellow. For coarse aggregate Wv 1.20 gr/cm3, BJAH 2.61, WC 2.38%, MHB 6.59, C 0.80%. Mix Design for concrete compressive strength f'c 30 MPa : Cement 539.47 kg, Sand 747.56 kg, Crushed Stone 851.84 kg, Water 181.13 Kg, Sikament-NN 1.5% 2.72 KG Silica Fume 15% 80.92 Kg. The compressive strength of concrete at 28 days for normal concrete was 34.17 MPa, concrete with Sikament-NN 1.5% 36.09 MPa, concrete with Silica Fume 15% 34.36 MPa, concrete with a combination of the two added ingredients 35.13 MPa. The yield percentage at 28 days for normal concrete was 113.90%, concrete with Sikament-NN 1.5% 120.30%, concrete Silica Fume 15% 114.53%, concrete with a combination of both ingredients added 117.60%. Thus, from the results of the normal concrete compressive strength test, concrete with the addition of 1.5% Sikament-NN, concrete with the addition of 15% Silica Fume and a combination of the two added materials meets the design compressive strength of f'c 30 MPaReferences
ACI EI-07. (2007). American Concrete Institute.
Almufid, A. (2020). Perencanaan Beton Mutu Tinggi (Kuat Tekan Besar ) dengan bahan Tambahan. Jurnal Teknik, 1(2), 1–7. https://doi.org/10.31000/jt.v1i2.25
Astuti, S. I., Arso, S. P., & Wigati, P. A. (2015). ??No Title No Title No Title. Analisis Standar Pelayanan Minimal Pada Instalasi Rawat Jalan Di RSUD Kota Semarang, 3, 103–111.
Badan Standardisasi Nasional. (2002). Tata Cara Perhitungan Struktur Beton Untuk Bangunan Gedung. SNI 03-2847-2002. Bandung: Badan Standardisasi Nasional, 251.
Barita, H., Thobyhend, S., & Vector, J. (2019). “ ANALISIS KARAKTERISTIK MATERIAL QUARRY WAISALAK TERHADAP KUAT TEKAN BETON ” UNIVERSITAS KRISTEN INDONESIA MALUKU FAKULTAS TEKNIK – JURUSAN TEKNIK SIPIL AMBON. UKIM Library.
Candra, A. I., Suwarno, Wahyudiono, H., Anam, S., Aprillia, D., & Karisma. (2020). Kuat Tekan Beton Fc’ 21,7 MPa Menggunakan Water Reducing and High Range Admixtures. Jurnal CIVILLa, 5(1), 330–340.
Citrakusuma, J. L. (2012). Kuat Tekan Self Compacting Concrete dengan Kadar Superplasticizer yang Bervariasi.
Egziabher, T. B. G., & Edwards, S. (2013). http://e-journal.uajy.ac.id/11926/4/TS145023.pdf. Http://E-Journal.Uajy.Ac.Id/11926/4/TS145023.Pdf, 53(9), 1689–1699. http://e-journal.uajy.ac.id/11926/4/TS145023.pdf
Megasari, S. W., & Winayati, W. (2017). Analisis Pengaruh Penambahan Sikament-Nn Terhadap Karakteristik Beton. SIKLUS: Jurnal Teknik Sipil, 3(2), 117–128. https://doi.org/10.31849/siklus.v3i2.398
Necrologica, N. (1981). R ?m R ?m. Ameghiniana, 720.
PBI 1971 N.I. - 2. (1971). Peraturan Beton Bertulang indonesia 1971 N.I. - 2. Jakarta: Direktorat Penyelidikan Masalah Bangunan, 7, 130.
Sihombing, L. (2017). Pengaruh penambahan sika fume® terhadap kuat tekan beton porous.
SNI 03-2834-2000. (2000). SNI 03-2834-2000: Tata cara pembuatan rencana campuran beton normal. Sni 03-2834-2000, 1–34.
SNI 15-2049. (2004). Semen Portland. Badan Standardisasi Nasional Indonesia, 1–128.
Teknik, F., & Sipil, J. T. (2010). Diktat Panduan Praktikum Beton Laboratorium Struktur UKIM (Issue 0911)
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.