Potensi Mata Air Aer Babunyi Dan Rancangan Sistem Pipa Untuk Penyediaan Air Bersih Di Negeri Porto, Provinsi Maluku

Penulis

  • Daniel F.W Sahertian Universitas Pattimura
  • Warniyati . Universitas Pattimura
  • Monica Rina Tutkey Universitas Pattimura
  • Tri Octaviani Sihombin Universitas Pattimura

DOI:

https://doi.org/10.51135/manumatav9i2p138-146

Kata Kunci:

water demand, springs, head loss, pump capacity

Abstrak

The people of Negeri Porto in Central Maluku Regency have the problem of clean water which is not sufficient for their needs. There is a spring that has not been managed properly, namely the Aer Babunyi. The spring is 7 km far from the center of Negeri Porto, so it is necessary to find a solution so that the water is easily accessible to people, then plan a reservoir before distributing it to residential areas. In this research, water discharge measurements use the containment method, water quality testing in the laboratory, population projections use the least squares method, head loss analysis use the Hazen William equation. The results show that the spring water discharge is 0.96 l/sec while it quality meets physical, chemical and microbiological standards. The average daily requirement (Qr) is 1,631 l/sec, the maximum daily requirement is 1,957 l/sec, and the peak daily requirement is 3,424 l/sec. The spring discharge is able to meet 28% of water demand of Porto’s people. Planning a pipeline network with a length of 1631.97 m, using a pump with a head of 58 m, pump operating time is 6 hours, pump capacity is 0.230 l/sec, and pump power is 2500 watts. The dimension of reservoir are 5mx5mx3.5m.

Referensi

Astiti, S.P.C, 2023, Penerapan Metode Least Square Dalam Perhitungan Proyeksi Jumlah Penduduk, SEPREN:Jurnal of Methematics Education and Applied, Vol.04, No.02, pp.147-154.

https://doi.org/10.36655/sepren.v4i1

BPS Kabupaten Maluku Tengah, 2021, Kecamatan Saparua Dalam Angka

Kemenkes, 2010, Peraturan Menteri Kesehatan Republik Indonesia No.492/Menkes/PER/IV2010

PUPR, 2007, Modul Proyeksi Kebutuhan Air Dan Identifikasi Pola Fluktuasi Pemakaian Air. Perencanaan Jaringan Pipa Transmisi Dan Distribusi Air Minum, 1–16.

SNI 7509, 2011, Tata Cara Perencanaan Tehnik Jaringan Distribusi Dan Unit Pelayanan Sistem Penyediaan Air Minum, Jakarta.

Sularso, Tahara H, 1991, Pompa dan Kompresor, Pradnya Paramitha, Jakarta.

Tiwery, C.J & Hully, A., 2021, Analisa Sistem Distribusi Air Bersih Tahun 2020-2040 Di Desa Negeri Lama Kecamatan Baguala, Kota Ambon, (Studi Kasus RT 01, 02/RW 01 Dan RT 09/RW 04), Jurnal Manumata, Vol.7, No. 1.

Diterbitkan

2024-03-28